Rainbow Electronics W90P710CDG User Manual

Page 119

Advertising
background image

W90P710CD/W90P710CDG

Publication Release Date: September 19, 2006

- 119 -

Revision B2

BITS

DESCRIPTIONS

[31:0] Length/Type

Length/Type Field of PAUSE Control Frame
In the PAUSE control frame, a length/type field is
defined and will be 16’h8808.

[15:0] OP-Code

OP Code Field of PAUSE Control Frame
In the PAUSE control frame, an op code field is defined
and will be 16’h0001.

CAM15L

31

30

29

28

27

26

25

24

Operand (MSB)

23

22

21

20

19

18

17

16

Operand

15

14

13

12

11

10

9

8

Reserved

7

6

5

4

3

2

1

0

Reserved

BITS

DESCRIPTIONS

[31:16] Operand

Pause Parameter, In the PAUSE control frame, an operand field is
defined and controls how much time the destination Ethernet MAC
Controller is paused. The unit of the operand is the slot time, the 512
bits time.

[15:0]

Reserved