W90P710CD/W90P710CDG

Publication Release Date: September 19, 2006

- 495 -

Revision B2

BITS

DESCRIPTIONS

[31:24]

DZI1

DZI1: Dead zone interval register 1, these 8-bit determine dead zone

length.
The 1 unit time of dead zone length is received from clock selector 2.

[23:16]

DZI0

DZI0: Dead zone interval register 0, these 8-bit determine dead zone
length.
The 1 unit time of dead zone length is received from clock selector 0.

[15:8]

CP1

CP1 : Clock prescaler 1 for PWM Timer channel 2 & 3
Clock input is divided by (CP1 + 1) before it is fed to the counter. 2 & 3
If CP1=0, then the prescaler 1 output clock will be stopped.

[7:0]

CP0

CP0 : Clock prescaler 0 for PWM Timer channel 0 & 1
Clock input is divided by (CP0 + 1) before it is fed to the counter. 0 & 1
If CP0=0, then the prescaler 0 output clock will be stopped.

PWM Clock Select Register (PWM_CSR)

REGISTER ADDRESS R/W

DESCRIPTION

RESET

VALUE

PWM_CSR

0xFFF8_7004

R/W PWM Clock Select Register

0x0000_0000

31

30

29

28

27

26

25

24

Reserved

23

22

21

20

19

18

17

16

Reserved

15

14

13

12

11

10

9

8

Reserved

CSR3

Reserved

CSR2

7

6

5

4

3

2

1

0

Reserved

CSR1

Reserved

CSR0

BITS

DESCRIPTIONS

[14:12]

CSR3

Select clock input for channel 3

[10:8]

CSR2

Select clock input for channel 2.

[6:4]

CSR1

Select clock input for channel 1

[2:0]

CSR0

Select clock input for channel 0