Rainbow Electronics W90P710CDG User Manual

Page 188

Advertising
background image

W90P710CD/W90P710CDG

- 188 -

31

30

29

28

27

26

25

24

POTPGT

23

22

21

20

19

18

17

16

Reserved

15

14

13

12

11

10

9

8

Reserved

OCPM

OCPM

DEVT

NPSW

PSWM

7

6

5

4

3

2

1

0

NDSP

BITS DESCRIPTION

[31:24]

POTPGT

PowerOnToPowerGoodTime

This field value is represented as the number of 2 ms intervals, which ensuring
that the power switching is effective within 2 ms. Only bits [25:24] is implemented
as R/W. The remaining bits are read only as ‘0’. It is not expected that these bits
be written to anything other than 1h, but limited adjustment is provided. This field
should be written to support system implementation. This field should always be
written to a non-zero value.

[23:13]

Reserved

Reserved. Read/Write 0's

[12]

NOCP

NoOverCurrentProtection

Global over-current reporting implemented in HYDRA-2. This bit should be written
to support the external system port over-current implementation.

0 = Over-current status is reported

1 = Over-current status is not reported

[11]

OCPM

OverCurrentProtectionMode

Global over-current reporting implemented in HYDRA-2. This bit should be written
0 and is only valid when NoOverCurrentProtection is cleared.

0 = Global Over-Current

1 = Individual Over-Current

[10]

DEVT

DeviceType

table of none-4is not a compound device.

[9]

NPSW

NoPowerSwitching

Global power switching implemented in HYDRA-2. This bit should be written to
support the external system port power switching implementation.

0 = Ports are power switched.

1 = Ports are always powered on.

[8]

PSWM

PowerSwitchingMode

Global power switching mode implemented in HYDRA-2. This bit is only valid
when NoPowerSwitching is cleared. This bit should be written '0'.

0 = Global Switching

1 = Individual Switching

[7:0]

NDSP

NumberDownstreamPorts

table of none-4 supports two downstream ports.

Advertising