W90P710CD/W90P710CDG

- 460 -

Continued

BITS

DESCRIPTIONS

[2:0]

TOC2,
TOC1,
TOC0

TOC5, TOC4, TOC3 (Time Out Configuration) control 8 bit time-out
counter 0 configuration.

TOC2,
TOC1,
TOC0
value

OPERATION MODE

000

8 bit counter 0 is stopped

001

Counting the value stored in register TOIR 0 is started
after 001b is written in register in register TOC. An
interrupt is given if enabled, and bit TO0 is set within
register SCSR when the terminal count is reached. The
counter is stopped by writing 000b in register TOC, and
should be stopped before reloading new values in register
TOC.

010

Counter 0 starts counting the content of register TOIR0 on
the first START bit (reception or transmission) detected on
the pin I/O after 010b is written in register TOC. When
counter 0 reaches its terminal count, an interrupt is given if
enable. Bit TO0 in register SCSR is set. The counter is
reloaded with TOIR0 and starts counting on each
subsequent START bit. It is possible to change the
content of TOIR0 during a count; the current count will not
be affected and the new count value will be taken into
account at the next START bit. The count is stopped by
writing 000b in register TOC,

011

Counter 0 starts counting the content of register TOIR0 on
the first START bit (reception or transmission) detected on
the pin I/O after 010b is written in register TOC. When
counter 0 reaches its terminal count, an interrupt is given if
enable. Bit TO0 in register SCSR is set. The count is
stopped by writing 000b in register TOC,

100

Same as value 000b, except that counter 0 will be stopped
at the end of the 12

th

ETU following the first START bit

detected after 100b has been written in register TOC