21.3 Hardware Version 1

21.3.1 PIN Assignment for Power Supply Level

(Power Supply)

Pin No.

Signal

Function

Input or Output Type

1

L

Net Supply

17

N

AC_Power_IN

100 – 240 V AC, 50/60 Hz

33 PE

2

L

18

N

AC_Power_OUT

100 – 240 V AC, 50/60 Hz

34

PE

3

L

19

N

AC_Power_OUT

100 – 240 V AC, 50/60 Hz

35 PE

4

L

20

N

AC_Power_OUT

100 – 240 V AC, 50/60 Hz

36

PE

5

L

21

N

AC_Power_OUT

100 – 240 V AC, 50/60 Hz

37 PE

6

L

22

N

AC_Power_OUT

100 – 240 V AC, 50/60 Hz

38

PE

7

NC

23 NC

--

39 NC

8

break contact

24

center

Relay 1

On/Off or PFM or PWM

40

make contact

9

NC

25 NC

--

41 NC

10

break contact

26

center

Relay 2

On/Off or PFM or PWM

42

make contact

11

NC

27 NC

--

43 NC

12

break contact

28

center

Relay 3

On/Off or PFM or PWM

44

make contact

13

NC

29 NC

--

45 NC

14

break contact

30

center

Relay 4

On/Off or PFM or PWM

46

make contact

15

NC

31 NC

--

47 NC

16

break contact

32

center

Relay 5

On/Off or PFM or PWM

48

make contact

Advertising