8 data logging / calibration / clock, Mxcontrol type 8620, Page 175 – Burkert Type 8620 User Manual

Page 175

Advertising
background image

mxCONTROL Type 8620


Page 175

21.5.8 Data Logging / Calibration / Clock

Configuration

BW 06T

System settings
Up-/Download

Data Logging

ENTER

6

EXIT

to Item

6-8

from Item

6-8

from Item

6-1

to Item

6-1

EXIT

to Item

5

from Item

5

...

...

Use the Arrow-Up-/Down-Softkeys
for scrolling through the list.

ENTER

----- SD-Card -----

Data Logging

EXIT

SELEC

6-3

Enable

Disable
Tsample 3600s

( x )

( x )

Code-Protection:
Operator or
Specialist Level

( */** )

Reinit

Reinit

( */** )

New settings of
Tsample apply when
returning to the Main
Menu Level.

( x )

Menu items „EventLog“ and „Log events“
are only visible with CodeLevel Specialist.

Tsample 3600s

Data Logging

EXIT

ENTER

6-8

LogFile

EventLog On
Log events

Configuration
Data Logging on SD-Card
- Enable/Disable (immediately
visible by the symbol top
left on the display )
- Sample Time (e.g. each
3600s one data sample)

System settings

BW 06T

Up-/Download
Data Logging

Calibration

ENTER

7

No

Up-/Download processes

on SD-Card are possible
during active Data Logging.

!

Sa, 2008-10-27

14:26:10

BW 06T

ENTER

Clock

------- Set -------

Clock

Time 14:26:10

Date 2008-10-27
===================

EXIT

INPUT

8-2

EXIT

ENTER

from Item

1

to Item

1

Use the Arrow-Up-/
Down-Softkeys for
scrolling through the list.

Internal Clock
- Set Time
- Set Date

!

If the Internal Clock is set, the Biocid Dosing
Module will be reinitialised.
That means that all active dosing events of this
module will be cancelled !!!

from Item

8-3

to Item

8-3

( */** )

ENTER

( x )

Reinit

( ** )

EXIT

Inputs

Calibration

EXIT

ENTER

7-1

Outputs

===================

ENTER

EXIT

AnalogIn 1

Inputs

EXIT

ENTER

7-1-1

AnalogIn 2

AnalogIn 3
AnalogIn 4

ENTER

EXIT

Factory Values
Press YES-Softkey
continuously for 4
seconds to restore
the factory
calibration values
of this 4-20mA
output.

EXIT

( x )

Reinit

Inputs

Calibration

EXIT

ENTER

7-2

===================

Outputs

ENTER

EXIT

4-20mA Output 1

Outputs

EXIT

ENTER

7-2-1

4-20mA Output 2

4-20mA Output 3
4-20mA Output 4

to Item

7-2-1-4

from Item

7-2-1-4

from Item

7-2-1-4

to Item

7-2-1-4

ENTER

EXIT

Offset 4.00mA

4-20mA Output 1

INPUT

7-2-1-1

Span 20.00mA

Factory Values
End

Offset 4.00mA

4-20mA Output 1

YES

7-2-1-3

Span 20.00mA

Factory Values

End

EXIT

...

...

For details
see chapter
„Inputs“, section
„Analog Inputs“,
paragraph „User
Calibration“ of
4...20mA inputs

For details
see chapter
„Outputs“, section
„Analog 4...20mA
Outputs“,
paragraph „Calibra-
tion of 4...20mA
outputs“

Submenu LogFile contains settings for current log
file name and for Log File Size limitation.

Only if Datalog Failed alarm is
active

, menu item 6-1 will be

displayed as a full screen for
alarm reset

.

--- Calibration ---

AnalogIn 1

EXIT

ENTER

7-1-1-1

2-point

Manual

1-point