4 hardware version 2 – Burkert Type 8620 User Manual

Page 162

Advertising
background image

mxCONTROL Type 8620


Page 162

21.4 Hardware version 2

21.4.1 PIN assignment for power supply level

(power supply)

Pin No.

Signal

Function

Input or Output Type

1

break contact

2

center

Relay 1

On/Off or PFM or PWM

3 make

contact

4

L

5

N

AC_Power_OUT

100 – 240 V AC, 50/60 Hz

6 PE

7

break contact

8

center

Relay 2

On/Off or PFM or PWM

9

make contact

10

L

11

N

AC_Power_OUT

100 – 240 V AC, 50/60 Hz

12

PE

13

break contact

14

center

Relay 3

On/Off or PFM or PWM

15 make

contact

16

L

17

N

AC_Power_OUT

100 – 240 V AC, 50/60 Hz

18 PE

19

break contact

20

center

Relay 4

On/Off or PFM or PWM

21

make contact

22

L

23

N

AC_Power_OUT

100 – 240 V AC, 50/60 Hz

24

PE

25

break contact

26

center

Relay 5

On/Off or PFM or PWM

27 make

contact

28

L

29

N

AC_Power_OUT

100 – 240 V AC, 50/60 Hz

30 PE

31

L

32

N

Internal power

100 – 240 V AC, 50/60 Hz

33

PE

supply

34

L

35

N

AC_Power_IN

Net Supply

36

PE

100 – 240 V AC, 50/60 Hz

Advertising