Trend file, Plc block transfer instruction data, Setup data full – Rockwell Automation 1336T ControlNet Frn1.02 Rev 1.5 User Manual

Page 109

Advertising
background image

4–67

Using Unscheduled Messaging

Publication 1336 FORCE–5.18 ––March, 1999

The Setup Data Full function allows you to write the trend set up
information in a single message.

If the set up data write is successful, it will auto-start the trend.

PLC Block Transfer Instruction Data

PLC Message Write instruction length:

15 words

PLC Message Read instruction length:

3 words

Header

Word 1

Header

Word 1

Header

Word 2

Header

Word 2

Header

Word 3

Trend Number

Message Structure

Header

Word 3

Trend Number

PLC Decimal Value

–28670

PLC Decimal Value

4098 –– Message OK

–28670 –– Message Error

Message Length

15

Message Length

3

PLC Request –– PLC Message Write

Drive Response –– PLC Message Read

Data

Word 4

Data

Word 5

Data

Word 6

Post Samples

Trend Sample Size

Trend Status

Data

Word 7

Data

Word 8

Data

Word 9

Mode

Sample Time Rate

Operator Data

Data

Word 10

Data

Word 11

Data

Word 12

Comparison B Value

Comparison A Link

Comparison A Value

Data

Word 13

Data

Word 14

Data

Word 15

Trend Output Parameter

Sampling Input Parameter

Comparison B Link

Trend File

Setup Data Full