Rockwell Automation 1336T ControlNet Frn1.02 Rev 1.5 User Manual

Page 162

Advertising
background image

6–20

Parameters

Publication 1336 FORCE–5.18 ––March, 1999

349

Data Output D1

[Data Out D1]

Data Out D1 contains the seventh image word from
the SCANport input image table.

Parameter Number

349

Parameter Type

Read/Write, Sink

Display Units / Drive Units

None

Factory Default

0

Minimum Value

0 Hex

Maximum Value

FFFF Hex

File – Group

Communications I/O – SCANport I/O

350

Data Output D2

[Data Out D2]

Data Out D2 contains the eighth image word from
the SCANport input image table.

Parameter Number

350

Parameter Type

Read/Write, Sink

Display Units / Drive Units

None

Factory Default

0

Minimum Value

0 Hex

Maximum Value

FFFF Hex

File – Group

Communications I/O – SCANport I/O

351

CntlNet Out 0

[CntlNet Out 0]

CntlNet Out 0 contains the first word or data group
to the PLC controller input image table. The data is
transferred to the PLC controller every rack scan.
The ControlNet Adapter Board can provide this
value directly. Other drive functions can provide this
value through a configuration link.

Parameter Number

351

Parameter Type

Read/Write, Sink

Display Units / Drive Units

None

Factory Default

None

Minimum Value

–32767

Maximum Value

+32767

File – Group

Communications I/O – Channel A

352

CntlNet Out 1

[CntlNet Out 1]

CntlNet Out 1 contains the second word or data
group to the PLC controller input image table. The
data is transferred to the PLC controller every rack
scan. The ControlNet Adapter Board can provide
this value directly. Other drive functions can provide
this value through a configuration link.

Parameter Number

352

Parameter Type

Read/Write, Sink

Display Units / Drive Units

None

Factory Default

None

Minimum Value

–32767

Maximum Value

+32767

File – Group

Communications I/O – Channel A