Parameters

Publication 1336 FORCE–5.18 ––March, 1999

473

Trend Output 2

[Trend Out 2]

Trend Out 2 displays the latest 500 trend input data
values once the trigger condition is true and all post
samples are gathered. This parameter is updated at
the same rate as the data was sampled. This
parameter can be linked to Analog Output (for
example) and a chart recorder connected to Analog
Output to provide a hard copy of the trend data.

Parameter Number

473

Parameter Type

Read Only, Source

Display Units / Drive Units

None

Factory Default

0

Minimum Value

–32767

Maximum Value

+32767

File – Group

Diagnostics – Trend I/O

474

Trend Input 3

[Trend In 3]

Trend In 3 specifies the data value to sample at the
specified trend sample rate. You should link Trend
In 3 to a source parameter (such as velocity, torque,
or current) for the trend to make sense.

Parameter Number

474

Parameter Type

Read/Write, Sink

Display Units / Drive Units

Dependent on Link➀

Factory Default

0

Minimum Value

–32767➀

Maximum Value

+32767➀

File – Group

Diagnostics – Trend I/O

➀ These values depend on the source parameter that this parameter is linked to.
For example, if the source parameter’s drive units are rpm, then Trend In 3’s drive
units will be displayed in rpm. The minimum and maximum values are also link
dependent.

475

Trend 3 Operand Parameter X

[Tr3 Opnd Parm X]

Tr3 Opnd Parm X specifies the first of two parameter
numbers for the trend trigger evaluation. The data
value for the entered link parameter number is used
in the trigger evaluation.

Parameter Number

475

Parameter Type

Read/Write, Sink

Display Units / Drive Units

Dependent on Link➀

Factory Default

0

Minimum Value

–32767➀

Maximum Value

+32767➀

File – Group

Diagnostics – Trend Setup

➀ These values depend on the source parameter that this parameter is linked to.
For example, if the source parameter’s drive units are rpm, then Tr3 Opnd Parm X’s
drive units will be displayed in rpm. The minimum and maximum values are also
link dependent.

476

Trend 3 Operand Parameter Y

[Tr3 Opnd Parm Y]

Tr3 Opnd Parm Y specifies the second of two
parameter numbers used for the trend trigger
evaluation. The data value for the entered link
parameter number is used in the trigger evaluation.

Parameter Number

476

Parameter Type

Read/Write, Sink

Display Units / Drive Units

Dependent on Link➀

Factory Default

0

Minimum Value

–32767➀

Maximum Value

+32767➀

File – Group

Diagnostics – Trend Setup

➀ These values depend on the source parameter that this parameter is linked to.
For example, if the source parameter’s drive units are rpm, then Tr3 Opnd Parm Y’s
drive units will be displayed in rpm. The minimum and maximum values are also
link dependent.