Rockwell Automation 1336T ControlNet Frn1.02 Rev 1.5 User Manual
Page 205
8–3
Using the Trend Features
Publication 1336 FORCE–5.18 ––March, 1999
5. Select the number that corresponds to the desired operator using
the table below:
Number
This
Operator
Compare:
0
GT (Greater Than)
Data Values for X and Y
1
LT (Less Than)
Data Values for X and Y
2
EQ (Equal)
Data Values for X and Y
3
NE (Not Equal)
Data Values for X and Y
4
AND
16–bit word in X to a 16 bit mask in Y
5
NAND (Negated AND)
16–bit word in X to a 16 bit mask in Y
6
OR
16–bit word in X to a 16 bit mask in Y
7
NOR (Negated OR)
16–bit word in X to a 16 bit mask in Y
Important: Remember that the trigger condition is compared in the
following manner [Variable X] [Operator] [Variable Y].
6.
If you are programming
Trend:
Then enter the operator in:
1
Parameter 457
2
Parameter 467
3
Parameter 476
4
Parameter 486
"