8–3

Using the Trend Features

Publication 1336 FORCE–5.18 ––March, 1999

5. Select the number that corresponds to the desired operator using

the table below:

Number

This

Operator

Compare:

0

GT (Greater Than)

Data Values for X and Y

1

LT (Less Than)

Data Values for X and Y

2

EQ (Equal)

Data Values for X and Y

3

NE (Not Equal)

Data Values for X and Y

4

AND

16–bit word in X to a 16 bit mask in Y

5

NAND (Negated AND)

16–bit word in X to a 16 bit mask in Y

6

OR

16–bit word in X to a 16 bit mask in Y

7

NOR (Negated OR)

16–bit word in X to a 16 bit mask in Y

Important: Remember that the trigger condition is compared in the
following manner [Variable X] [Operator] [Variable Y].

6.

If you are programming

Trend:

Then enter the operator in:

1

Parameter 457

2

Parameter 467

3

Parameter 476

4

Parameter 486

"

Advertising