6–18

Parameters

Publication 1336 FORCE–5.18 ––March, 1999

339

Analog Input 1

[Analog In 1]

Analog In 1 displays the result of converting a

±

10V

signal to a

±

32767 value using Analog In 1 Scale

(parameter 393) and Analog In 1 Offset (parameter
392). You can link this digital value to other 1336
FORCE parameters.

Parameter Number

339

Parameter Type

Read Only, Source

Display Units / Drive Units

None

Factory Default

0

Minimum Value

–32767

Maximum Value

+32767

File – Group

Communications I/O – Analog Input

340

Analog Input 2

[Analog In 2]

Analog In 2 displays the result of converting a

±

10V

signal to a

±

32767 value using Analog In 2 Scale

(parameter 395) and Analog In 2 Offset (parameter
394). You can link this digital value to other 1336
FORCE parameters.

Parameter Number

340

Parameter Type

Read Only, Source

Display Units / Drive Units

None

Factory Default

0

Minimum Value

–32767

Maximum Value

+32767

File – Group

Communications I/O – Analog Input

341

Analog Input 3

[Analog In 3]

Analog In 3 displays the result of converting a

±

10V

signal to a

±

32767 value using Analog In 3 Scale

(parameter 397) and Analog In 3 Offset (parameter
396). You can link this digital value to other 1336
FORCE parameters.

Parameter Number

341

Parameter Type

Read Only, Source

Display Units / Drive Units

None

Factory Default

0

Minimum Value

–32767

Maximum Value

+32767

File – Group

Communications I/O – Analog Input

342

Analog Input 4

[Analog In 4]

Analog In 4 displays the result of converting a

±

10V

signal to a

±

32767 value using Analog In 4 Scale

(parameter 399) and Analog In 4 Offset (parameter
398). You can link this digital value to other 1336
FORCE parameters.

Parameter Number

342

Parameter Type

Read Only, Source

Display Units / Drive Units

None

Factory Default

0

Minimum Value

–32767

Maximum Value

+32767

File – Group

Communications I/O – Analog Input

Advertising