6–21

Parameters

Publication 1336 FORCE–5.18 ––March, 1999

353

CntlNet Output 2

[CntlNet Out 2]

CntlNet Out 2 contains the third word or data group
to the PLC controller input image table. The data is
transferred to the PLC controller every rack scan.
The ControlNet Adapter Board can provide this
value directly. Other drive functions can provide this
value through a configuration link.

Parameter Number

353

Parameter Type

Read/Write, Sink

Display Units / Drive Units

None

Factory Default

None

Minimum Value

–32767

Maximum Value

+32767

File – Group

Communications I/O – Channel A

354

CntlNet Output 3

[CntlNet Out 3]

CntlNet Out 3 contains the fourth word or data group
to the PLC controller input image table. The data is
transferred to the PLC controller every rack scan.
The ControlNet Adapter Board can provide this
value directly. Other drive functions can provide this
value through a configuration link.

Parameter Number

354

Parameter Type

Read/Write, Sink

Display Units / Drive Units

None

Factory Default

None

Minimum Value

–32767

Maximum Value

+32767

File – Group

Communications I/O – Channel A

355

CntlNet Output 4

[CntlNet Out 4]

CntlNet Out 4 contains the fifth word or data group
to the PLC controller input image table. The data is
transferred to the PLC controller every rack scan.
The ControlNet Adapter Board can provide this
value directly. Other drive functions can provide this
value through a configuration link.

Parameter Number

355

Parameter Type

Read/Write, Sink

Display Units / Drive Units

None

Factory Default

None

Minimum Value

–32767

Maximum Value

+32767

File – Group

Communications I/O – Channel A