Using Unscheduled Messaging

Publication 1336 FORCE–5.18 ––March, 1999

If an error occurs in the PMW, a value of -29952 is returned in word
2 of the PMR response.

Example

In this example, a reference time stamp data read was requested
through the PMW. Word 2 of the PMW defines this request with a
decimal value of 2816 for the PLC command code. The PMR
response indicates a successful request with a returned value of 2816
in PMR word 2. Words 4 through 7 then return the clock data. The
clock data indicates a time stamp of February 1995, the fifth day of
the week (Thursday), and a date of 23 (17 in ASCII). The hour,
minutes, and seconds change according to the time.

1

0

N7:10

2

3

4

5

6

7

8

9

N7:10

PLC MSG
Write File

PLC MSG
Read File

Data Format

0

0

7681

3

0

2816

2816

3594

5893

1282

N7:90

0E\01 0E\0A 17\05 05\02

S\..01S

Hr\Min Date\Day Yr\Mth

ASCII Display Values

Reference Time Stamp Data
Read