Rockwell Automation 1336T ControlNet Frn1.02 Rev 1.5 User Manual

Page 186

Advertising
background image

6–44

Parameters

Publication 1336 FORCE–5.18 ––March, 1999

485

Trend 4 Operand Parameter X

[Tr4 Opnd Parm X]

Tr4 Opnd Parm X specifies the first of two parameter
numbers for the trend trigger evaluation. The data
value for the entered link parameter number is used
in the trigger evaluation.

Parameter Number

485

Parameter Type

Read/Write, Sink

Display Units / Drive Units

Dependent on Link➀

Factory Default

0

Minimum Value

–32767➀

Maximum Value

+32767➀

File – Group

Diagnostics – Trend Setup

➀ These values depend on the source parameter that this parameter is linked to.
For example, if the source parameter’s drive units are rpm, then Tr4 Opnd Parm X’s
drive units will be displayed in rpm. The minimum and maximum values are also
link dependent.

486

Trend 4 Operand Parameter Y

[Tr4 Opnd Parm Y]

Tr4 Opnd Parm Y specifies the second of two
parameter numbers used for the trend trigger
evaluation. The data value for the entered link
parameter number is used in the trigger evaluation.

Parameter Number

486

Parameter Type

Read/Write, Sink

Display Units / Drive Units

Dependent on Link➀

Factory Default

0

Minimum Value

–32767➀

Maximum Value

+32767➀

File – Group

Diagnostics – Trend Setup

➀ These values depend on the source parameter that this parameter is linked to.
For example, if the source parameter’s drive units are rpm, then Tr4 Opnd Parm Y’s
drive units will be displayed in rpm. The minimum and maximum values are also
link dependent.

487

Trend 4 Operator

[Tr4 Operator]

Tr4 Operator specifies the operator used for the
trend trigger evaluation. The available operators
are:

Value

Description

1

Greater Than

(.GT.)

2

Less Than

(.LT.)

3

Equals

(.EQ.)

4

Not Equals

(.NE.)

5

Logical AND

(.AND.)

6

Logical NAND (.NAND.)

7

Logical OR

(.OR.)

8

Logical NOR

(.NOR.)

Parameter Number

487

Parameter Type

Read/Write, Non–Linkable Sink

Display Units / Drive Units

None

Factory Default

5

Minimum Value

1

Maximum Value

8

File – Group

Diagnostics – Trend Setup

488

Trend 4 Sample Rate

[Tr4 Sample Rate]

Tr4 Sample Rate specifies the interval at which the
data in the Trend In 4 parameter is sampled. It is
programmable in 2 millisecond increments. All
values are rounded down to the nearest 2
millisecond interval.

Parameter Number

488

Parameter Type

Read/Write, Non–Linkable Sink

Display Units / Drive Units

Seconds

Factory Default

0.020 Seconds

Minimum Value

0.002 Seconds

Maximum Value

30 Seconds

File – Group

Diagnostics – Trend Setup

Advertising