Retentive up/down counters c7 and c8, Retentive up/down counters c7 and c8 -14, How the retention works – Rockwell Automation 1760-xxxx Pico Controller User Manual User Manual

Page 164: Examples, Counting parts

Advertising
background image

Publication 1760-UM001D-EN-P - September 2005

7-14 Retention

Retentive Up/Down
Counters C7 and C8

How the Retention Works

The actual values of counters C7 and C8 are retentive. When the
condition for resetting the counter is satisfied, the actual value of the
counter will be reset.

Examples

Counting Parts

Task 1
Parts are packed automatically in a shipping carton. Even if there is a
power outage, the correct number should still be packed into the
carton. When the carton is full, the carton is removed manually and
the counter is reset.

Contacts and relays used:

Signal diagram:

U = Supply voltage

Coil

Function

I5

Count parts

I6

Reset counter

Q1

Carton Full, signal lamp

C8

Up counter

DIR

CNT

RES

C8

+

{

I5---------CC8

C8---------{Q1

I6-C8------RC8

0042

0036

Circuit Diagram:

Parameters entered:

U

a

a