Rockwell Automation 1760-xxxx Pico Controller User Manual User Manual

Page 76

Advertising
background image

Publication 1760-UM001D-EN-P - September 2005

4-16 Draw a Circuit Diagram with Pico

Relays with Output Energize Negate Function

Relays with Falling Edge Function

Physical outputs should not be used when a cycle pulse is generated.

Instruction Type

Representation in Pico

Output Relay Q

}Q1…}Q6

(depending on type)

Marker Relay M

}M1…}M16, }N1…}N16

Text Display Relay D

}D1…}D16

(1760-L18xxx)

Expansion or Marker Relay

}S1…}S8

(1760-L18xxx)

Jumps

}:1…}:8

(1760-L18xxx)

Instruction Type

Representation in Pico

Marker Relay M, N

è

M1…

è

M16,

è

N1…

è

N16

Jumps

и

:1…

и

:8

(1760-L18xxx)

The output signal is the opposite of the input signal;
the relay operates like a contactor with contacts
that have been negated. If the coil is energized
when ON, the coil switches its make contacts to the
OFF state.

on

on

Signal Diagram:

Input

Output

This function is used if the coil is only meant to
switch on a falling edge. With a change in the coil
state from closed to open, the coil switches the
make contacts to the closed state for one cycle.

on

on

Signal Diagram:

Input

Output

Advertising