Publication 1760-UM001D-EN-P - September 2005

8-6 Inside Pico

1760-L18xxx Cycle Time

For 1760-L18xxx, the cycle time can be calculated as follows:

List of Times for Processing Function Relays

Example: Operating Hours Counter

Function

Number

Time Duration in µs Total

Basic pulse

1

520

Refresh

5700

Contacts and bridged contact fields

40

Coils

20

Total rungs from the first one to the last
one, with empty ones in between

70

Connecting lines (only

)

40

Timing relays

Counters

Analog value function relays

Total

Number

1

2

3

4

5

6

7

8

Timing relays in µs

40

120

160

220

300

370

440

540

Counters in µs

40

100

160

230

300

380

460

560

Analog value processors in µs 120

180

220

260

300

360

420

500

,

,

-----------TT8

T8-M16-----CC8

-------SM16

T8--------RM16

C8---------{Q4

I1---------RC8

RT8