4.2.49.21 ipv6 mld snooping last-member-query-interval

Command:

ipv6 mld snooping last-member-query-interval <IpmcLmqi : 0-31744>

ipv6 IPv6 configuration commands

mld

Multicast Listener Discovery

snooping

Snooping MLD

last-member-query-interval

Last Member Query Interval in tenths of seconds

<IpmcLmqi : 0-31744>

0 - 31744 tenths of seconds

Default:

10

Usage Guide:

To configure Last-member-query-interval of MLD snooping for specific VLAN

Example:

To configure Last-member-query-interval (100 seconds) of MLD snooping for VLAN X

Switch# configure terminal

Switch (config)# interface vlan X
Switch (config-if-vlan)# ipv6 mld snooping last-member-query-interval 1000

4.2.49.22 ipv6 mld snooping priority

Command:

ipv6 mld snooping priority <CosPriority : 0-7>

ipv6 IPv6 configuration commands

mld

Multicast Listener Discovery

snooping

Snooping MLD

priority

Interface CoS priority

<CosPriority : 0-7>

CoS priority ranges from 0 to 7