Clock Circuitry

Clock Select Jumper (J19)

J19 determines which input to U16 (the selected clock oscillator or the
SMA clock will be used to determine the clock outputs of U16. See

Figure 2–22

and

Figure 2–23

.

Socket for a Custom Clock Oscillator (J20)

J20 is a socket for connecting a half-can oscillator that can be used instead
of the on-board clock oscillator (U20). An oscillator inserted into J20 is
called the custom clock and is not included in the DSP Development Kit,
Cyclone II Edition
. The custom oscillator can be selected to be the input to
U16.The J20 socket is mounted on top of U20, the on-board clock
oscillator, as shown in

Figure 2–22

.

D/A Converter CLK SMA Connector (J26)

J26 is an SMA connector that provides an external clock input to the D/A
converter. It can be selected to be the D/A converter clock. See

“D/A

Converter Clocks” on page 2–18

. J26 is shown in

Figure 2–7 on page 2–18

.

Table 2–12 on page 2–19

describes the D/A converter clock source

settings.

A/D Converter CLK SMA Connector (J27)

J27 is an SMA connector that provides an external clock input to the A/D
converter. It can be selected to be the A/D clock. See

“A/D Converter

Clocks” on page 2–23

. J27 is shown in

Figure 2–10 on page 2–23

.

Table 2–17 on page 2–24

describes the A/D converter clock source

settings.

D/A Converter CLK Select Jumper (J35 & J34)

J35 is used to choose between three clocking inputs to select the
DAC CHANNEL A clock. J34 is used to choose between three clocking
inputs to select the DAC CHANNEL B clock. The J35 and J34 D/A
converter clock select settings are described in

Table 2–12 on page 2–19

.

J35 and J34 are shown in

Figure 2–7 on page 2–18

.

A/D Converter CLK Select Jumper (J37 & J36)

J37 is used to choose between three clocking inputs to select the
ADC CHANNEL A clock. J36 is used to choose between three clocking
inputs to select the ADC CHANNEL B clock.The J37and J36 A/D
converter clock select settings are described in

Table 2–17 on page 2–24

.

J37 and H36 are shown in

Figure 2–10 on page 2–23

.