Power Supply
VCCA_ADC
A/D converter power
●
Remove fuse F7
●
Place a jumper on pins 2 and 3 on J28 to disable the
regulator
●
Apply 3.3 V to J42
●
Apply GND to J41
VCCA_DAC
D/A converter power
●
Remove fuse F6
●
Place a jumper on pins 2 and 3 on J25 to disable the
regulator
●
Apply 5 V to J39 and GND to J40
or
●
Apply 3.3 V to J39 and GND to J40
Table 2–36. Procedure for Powering Individual Power Planes Through Bench Power Supplies (Part 2 of 2)