Altera Cyclone II DSP Development Board User Manual

Page 78

Advertising
background image

2–70

Reference Manual

Altera Corporation

Cyclone II DSP Development Board

August 2006

Power Supply

VCCA_ADC

A/D converter power

Remove fuse F7

Place a jumper on pins 2 and 3 on J28 to disable the
regulator

Apply 3.3 V to J42

Apply GND to J41

VCCA_DAC

D/A converter power

Remove fuse F6

Place a jumper on pins 2 and 3 on J25 to disable the
regulator

Apply 5 V to J39 and GND to J40

or

Apply 3.3 V to J39 and GND to J40

Table 2–36. Procedure for Powering Individual Power Planes Through Bench Power Supplies (Part 2 of 2)

Power Plane

Power Plane Using Bench Power

Supplies

Settings

Advertising