Power Plane Connectors (J2-J6, J39 Through J42)

Bench power supplies provide an easy way to measure the current draw
on each power plane. When one plane is being powered by the bench
supply, all other planes still draw current from the DC power input. Upon
applying power to the Cyclone II DSP development board, the power
LED (D1) should be on.

Table 2–36

lists the procedure for powering individual planes through

bench power supplies. In the instructions, only remove the fuse listed in
the Settings column. Other fuses should be left on Cyclone II DSP
development board.

Table 2–36. Procedure for Powering Individual Power Planes Through Bench Power Supplies (Part 1 of 2)

Power Plane

Power Plane Using Bench Power

Supplies

Settings

3.3V

Cyclone II VCCIO banks 1, 2, 5, and 6,
clock oscillators and buffers, Expansion
Prototype Connector, SSRAM,
EPCS64, LEDs, Audio CODEC, Video
DAC, translators

Remove fuse F3

Apply 3.3 V to J4

Apply GND to J2

1.8V

DDR2 DIMM, Cyclone II VCCIO, banks
3, 4, 7, and 8

Remove fuse F2

Apply 1.8 V to J3

Apply GND to J2

6V

VCCA_ADC regulator, VCCA_DAC
regulator

There is no on-board provision to apply 6 V externally
or to remove the regulator from the circuit.

1.2V

Cyclone II VCCINT, VCCA_PLL, and
VCCD_PLL

Remove fuse F1

Apply 1.2 V to J5

Apply GND to J2

5V

Expansion Prototype Connector card
voltage limiters

Remove fuse F5

Place a jumper on pins 2 and 3 on J7 to disable the
regulator.

There is no on-board provision to apply 5 V externally.

VTT

DDR2 VTT power

Remove fuse F4

Apply 0.9 V to J6

Apply GND to J2