Configuration of digital inputs, logic state mode.

After selecting the configuration of an input in logic mode, you must select the input that you

want to configure in this mode:

Digital input 1.

Digital input 2.

When selecting the input to configure with the key

(

figure 136)

, you can program the input

logic.

figure 136: Digital inputs configuration screen (logic state mode).

The parameter selected is indicated in white.

The following options appear in the lower area:

Positive, the digital input logic is positive

Negative, the digital input logic is negative

Previous, selects the previous parameter

Next, selects the next parameter

Confirm, confirms and saves in the memory the values programmed on the screen

Back, returns to the main configuration screen for digital inputs

figure 133

.

Main Menu, back to the main menu,

figure 25

.