[Events]
Set the parameters for the events.

Figure 4-25

When Door Entry/Exit Control or Parking Entry/Exit Control is selected in the
Function Setting page (Figure 4-23), these options become available:

Option

Description

Anti-Passback

Enables or disables the Anti-Passback function. The option is only
available for Door/Gate A.

Gate Open Time

Sets the time (1 to 255 sec.) that a parking gate remains open after
which the gate will automatically be locked. The option is only
available when Parking Entry/Exit Control is selected.

Lock Reset Time

Sets the time (1 to 255 sec.) that a door remains open after which
the door will automatically be locked. The option is only available
when Door Entry/Exit Control is selected.

Held Open Time

Sets the time (5 to 9999 sec.) that a door/gate can be held open
before an alarm is generated.

Fire Action

Locks or unlocks the door/gate when a fire condition occurs.
Otherwise, remains the door’s current state by selecting
Unchanged.

Alarm Continuous
Time

Sets the time (1 to 10 sec.) that the alarm will continuously go off
before it ends.

When Elevator Control is selected in the Function Setting page (Figure 4-23), these
options become available:

Option

Description

Relay on Time

Sets the time (1 to 255 sec.) that an elevator door remains open
after which the door will automatically be closed.

Fire Action

Alarm Continuous
Time

See the same option above.