AGI Security GV-CONCT User Manual

Page 126

Advertising
background image

116

When Elevator Control is selected in the Function Setting page (Figure 4-23), these
Input Type and Input Function become available:

Input Type

Input Function

Description

Normal Input

Enable Latch
Disable Latch

See the same Input Type above.

Relay A or B

Fire Zone
Tamper Zone

See the “Door A or Door B” Input Type above.
For example, the Tamper Zone sensor is
installed on GV-ASBox. So whenever there is
any attempt to open the Box, the “Tamper” event
occurs and it may trigger the “Tamper” alarm.


[Output Function]

Here you can define each output device that is connected to GV-ASBox, such as locking
devices, various alarms or Exit Button. Only Output 5 to Output 8 can be connected to
Lights.

Select from the drop-down list to configure Output Type (No. 1, Figure 4-33). Depending on
the chosen Output Type, either Output Function (No. 2, Figure 4-33) or Output
Conditions
(No. 3, Figure 4-33) will become available.

Figure 4-33

Note: For alarm outputs, the corresponding alarms must be enabled (YES) in the
Parameter Setting page (Figure 4-24). If alarms are set to be disabled (NO), the alarm
function here will not work when triggered.

1

1

2

3

Output Function

Output Conditions

Output Type