Below is the explanation based on the numbers marked on the above figure.

1. Output Type: Configure the output type. Options available for the output type change

based on your settings of Door /Gate # in the Function Setting page (Figure 3-20).

2. Output Function: Configure the output function. Options available for the output

function change based on your setting of Output Type above.

When Door # is selected as Output Type, these Output Functions become available:

Output #

Output Type

Output Function

Description

Electric Lock

Output is triggered when the card
is presented to open the locking
device.

Event Alarm

Output is triggered when the
defined alarm events occur.

Security Card

Output is triggered when the
security card is presented.

Entry Card

Output is triggered when the card
is presented to enter the door.

Exit Card

Output is triggered when the card
is presented to exit the door.

Output 01 ~ 08

Door #

Door Open Alarm

Output is triggered when the door
is open.

Beeper

Green LED

Output 09 ~ 16

Door #

Red LED

These Output Functions are only
available for Output 9~ 16
because these outputs on GV-
AS400 cannot accept external
power supply.