E connecting output devices – AGI Security GV-CONCT User Manual

Page 98

Advertising
background image

88

4.1.4.E Connecting Output Devices

GV-ASBox provides 8 outputs and 2 auxiliary power outputs of 12V DC. The outputs are
divided into two groups, outputs 1 ~ 4 and outputs 5 ~ 8. Before connecting, make sure if
your output device meets any of the two different absolute maximum ratings listed below.

Additionally, you can wire the light switch to the outputs 5 ~ 8 for lighting control. When
the access is granted, the light is turned on; when the exit is granted, the light is turned off.
See To combine door access with relay activation below.

Figure 4-5

Outputs 1-4: Absolute Maximum Ratings

Breakdown Voltage

277V AC, 30V DC

Continuous Load Current

5A (NO), 3A (NC)

Note: Absolute Maximum Ratings are those values beyond which damage to GV-
ASBox circuit board may occur. Continuous operation of GV-ASBox at the absolute
rating level may affect GV-ASBox reliability.

Outputs 5-8: Absolute Maximum Ratings

Breakdown Voltage

240V AC, 30V DC

Continuous Load Current

16A (NO), 8A (NC)

Note: Absolute Maximum Ratings are those values beyond which damage to GV-
ASBox circuit board may occur. Continuous operation of GV-ASBox at the absolute
rating level may affect GV-ASBox reliability.

Advertising
This manual is related to the following products: