Optional Devices

109

4

[Alarm]

Select Yes or No to enable or disable the alarm function. If you have defined the alarm
conditions in [Output Function] of the In/Out Function page (Figure 4-31), remember to
activate the corresponding alarms here; otherwise, even though the alarm conditions are
met, the expected alarm will not be triggered. The default settings for all the alarms are set
to NO.

Figure 4-26

When Door Entry/Exit Control or Parking Entry/Exit Control is selected in the
Function Setting

page (Figure 4-23), these options become available:

Option

Description

Held Open

This alarm activates whenever the door is held open over the set

period of time.

Forced Open

This alarm activates whenever the door is opened by force.

Fire Alarm

This alarm activates whenever fire is detected.

Access Denied

This alarm activates whenever entry is denied due to using the

wrong card or entering the wrong password.

Tamper

This alarm activates whenever vandalism occurs, e.g. the opening

of Controller’s cabinet.

When Elevator Control is selected in the Function Setting page (Figure 4-23), these
options become available:

Option

Description

Fire Alarm

Access Denied

Tamper

See the same option above.