background image

GV-AS110 Controller

33

2

Event

Held Open Î 0
Forced Open Î 1
Tamper Î 2
Fire Alarm Î 3
Access Denied Î 4
Alarm Time Î 1-10 sec

1 to enable the option and 0 to disable the
option. For the third and fourth blank digits, type
the number of seconds the alarm will sound.
For example, to enable the fire alarm for 3
seconds, press *7233103#

Door/Gate

Function

343_#

Door Entry TypeÎ0
Parking Entry TypeÎ1
Door Exit TypeÎ2
Parking Exit TypeÎ3
Elevator TypeÎ4

„

Door Entry Type: Sets GV-AS110 as entry
reader of a door. The Wiegand reader
connected will be set as exit reader.

„

Parking Entry Type: Sets GV-AS110 as
entry reader of a parking gate.

„

Door Exit Type: Sets GV-AS110 as exit
reader of a door. The Wiegand reader
connected will be set as entry reader.

„

Parking Exit Type: Sets GV-AS100 as exit
reader of a parking gate.

„

Elevator Type: GV-AS100 reader is
installed in the elevator for access control.

For example, to set the GV-AS110 as an exit

reader of a door, press *3432#

Set

Authentication

Mode

526_#

Schedule ModeÎ0
Fixed Card ModeÎ1
Local Lock ModeÎ2
Local Unlock ModeÎ3
Fixed Card + PINÎ4
Fixed Card/CommonÎ5

„

Schedule Mode: Follows the
authentication schedule set on GV-
ASManager.

„

Fixed Card Mode: Grants access after the
card is presented. Ignores the
authentication schedule of GV-ASManager.

„

Local Lock Mode: Remains locked. The
locked state cannot be cleared through GV-
ASManager.

„

Local Unlock Mode: Remains open. The
held-open state cannot be cleared through
GV-ASManager.

„

Fixed Card + PIN: Grants access after the
user presents the card and then enters the
card’s PIN code. Ignores the authentication
schedule of GV-ASManager.

„

Fixed Card/Common: Grants access after
card is presented or after the door’s
password is entered. Ignores the
authentication schedule of GV-ASManager.

For example, to enable the Fixed Card + PIN

Advertising