Optional Devices

119

4

Output Condition Settings:

When Output Type

(No. 1, Figure 4-33) is set to be Normal, Toggle, Pulse, Normal

Lighting, Toggle Lighting or Pulse Lighting, the options similar to the figure below
become available.

Figure 4-35

There can be a maximum of 4 conditions that can be set up to trigger an output. 2 conditions
are Door/Gate/Relay conditions and 2 conditions are Input conditions. Each condition is
related to each other through AND/OR. AND means that all conditions with AND must be
triggered before the output is triggered. OR means that only 1 of the condition with OR is
needed to be triggered before the output is triggered. It is also valid to have certain
conditions as AND and certain conditions as OR.

Only Output 5 ~ 8 can be connected to Lights. So Normal Lightning, Toggle Lighting and
Pulse Lighting can only be selected from Output 5 ~ 8. For Pulse and Pulse Lighting, the
output is triggered for the amount of time set in the Sec field (seconds).

2 x Door/Gate/Relay Conditions

2 x Input Conditions

Available in
Pulse/Lighting

Advertising