E.b output condition settings – AGI Security GV-CONCT User Manual
Page 80
70
3.4.3.E.b Output Condition Settings
When Output Type (No. 1, Figure 3-27)
is set to be Normal, Toggle or Pulse, the options
similar to the figure below become available.
Figure 3-29
There can be a maximum of 4 conditions that can be set up to trigger an output. 2 conditions
are Door/Gate/Relay conditions and 2 conditions are Input/Reader conditions. Each
condition is related to each other through AND/OR. AND means that all conditions with AND
must be triggered before the output is triggered. OR means that only 1 of the condition with
OR is needed to be triggered before the output is triggered. It is also valid to have certain
conditions as AND and certain conditions as OR.
For Pulse output type, the output is triggered for the amount of time set in the Sec field
(seconds).
In the Output Condition settings, these Output Type and Output Condition become
available:
Output Condition
Output Type
Door #
Gate #
Relay #
Input/Reader
Access Granted Access Granted Access Granted
Access Denied
Access Denied
Access Denied
Fire Alarm
Fire Alarm
Fire Alarm
Tamper
Tamper
Tamper
Duress Event
Duress Event
Duress Event
Held Open
Held Open
Forced Open
Forced Open
Exit Button
Exit Button
Normal
Toggle
Pulse
Door Contact
Car Detection
Select None to
disable the
condition, or
select between
Input 1 and
Input 8,
Wiegand A and
Wiegand H, or
Reader 00 to
Reader 03 to
trigger the
output.
Available in Pulse
2 x Door/Gate/Relay Condition
2 x Input/Reader Condition