Vcm-x / rne status, Vcm-x / rne status screens, Vcm-x / rne operator interfaces technical guide 54 – Orion System VCM-X/RNE Operator Interfaces User Manual

Page 54

Advertising
background image

VCM-X / RNE STATUS

VCM-X / RNE Operator Interfaces Technical Guide

54

Status Screen 19 / VCM-X - Full Digital Module

OR Dual Digital Module

VCMX-M/HP Cnfg ID 102

Full Digital Temp

Coil A1: X.Xº F
Coil A2: X.Xº F

Line 2 Full Digital Temperature

If using a VCM-X Modular Controller ( OE332-23-VCMX-

MOD-A) with a Full Digital Module ( OE370-23-FD-A) or

if you are using the VCM-X WSHP Controller ( VCMX-23-

VCMX-WSHP-A) with multiple Digital Scroll

Compressors, this screen will appear.

Line 3 Coil A1 Temperature

This is the current Coil Suction Temperature of

Compressor

A1.

Line 4 Coil A2 Temperature

This is the current Coil Suction Temperature of

Compressor

A2.

Line 2 Dual Digital Temperature

If using a VCM-X Modular Controller ( OE332-23-VCMX-

MOD-C) with a Dual Digital Module ( OE370-23-DD) or

if you are using the VCM-X WSHP Controller ( VCMX-23-

VCMX-WSHP-C) with two Digital Scroll Compressors,

this screen will appear.

Line 3 Circuit A Temperature

This is the current Coil Suction Temperature of Circuit A.

Line 4 Circuit B Temperature

This is the current Coil Suction Temperature of Circuit B.

VCMX-M/HP Cnfg ID 102

Dual Digital Temp

Circuit A: X.Xº F
Circuit B: X.Xº F

Status Screen 19 / RNE - Full Digital Module

RNE Cnfg ID 102

Full Digital Temp

Coil A1: X.Xº F
Coil A2: X.Xº F

Line 2

Full Digital Temperature

If using a Full Digital Module ( OE370-23-FD-A) or

Water Source Heat Pump Module (OE334-23-WPM-A),

this screen will appear.

Line 3 Coil A1 Temperature

This is the current Coil Suction Temperature of

Compressor

A1.

Line 4 Coil A2 Temperature

This is the current Coil Suction Temperature of

Compressor

A2.

Status Screen 20 /

VCM-X

- Full Digital Module

Line 2 Full Digital Temperature

If using a VCM-X Modular Controller (OE332-23-VCMX-

MOD-A) with a Full Digital Module (OE370-23-FD-A) or

if you are using the VCM-X WSHP Controller (VCMX-23-

VCMX-WSHP-A) with at least two Digital Scroll

Compressors, this screen will appear. Values will show zero

if not using 4 Digital Scroll Compressors.

Line 3

Coil B1 Temperature

This is the current Coil Suction Temperature of

Compressor

B1.

Line 4

Coil B2 Temperature

This is the current Coil Suction Temperature of

Compressor

B2.

VCMX-M/HP Cnfg ID 102

Full Digital Temp

Coil B1: X.Xº F

Coil B2: X.Xº F

VCM-X / RNE Status Screens