1 operation in normal mode, Operation in normal mode – FUJITSU SOFTUNE F2 MC-16 User Manual

Page 104

Advertising
background image

90

CHAPTER 2 DEPENDENCE FUNCTIONS

2.2.6.1

Operation in Normal Mode

As shown in the figure below, the event trigger set in the normal mode performs input to
the sequencer. In the sequencer, either branching to any level, or terminating the
sequencer, can be specified as an operation at event trigger occurrence. This enables
debugging (breaks, limiting trace, measuring time) while monitoring program flow.

Operation in Normal Mode

The termination of sequencer triggers the delay counter. When the delay counter reaches the specified count,

sampling for the single trace terminates. A break normally occurs at this point, but if necessary, the program

can be allowed to run on without a break.

Figure 2.2-3 Operation in Normal Mode

Events

SET EVENT

CANCEL EVENT

SHOW TRACE/STATUS

SHOW DELAY

DISABLE EVENT

ENABLE EVENT

SHOW EVENT

SHOW SEQUENCE level

SET
SEQUENCE/EVENT

CANCEL
SEQUENCE/EVENT

SHOW SEQUENCE/ALL

SET DELAY

SET
SEQUENCE/TIMER

CANCEL
SEQUENCE/TIMER

SET SEQUENCE/DISABLE TRACE

SET SEQUENCE/ENABLE TRACE

SET SEQUENCE/NO TRACE

CLEAR TRACE

SEARCH TRACE

SHOW TRACE/DATA

ENABLE TRACE

DISABLE TRACE

SET TRACE

Enable/Disable
control

Enable

Disable

Select event number causing
trigger at each level, set
pass count value.

Timer setup
for each
condition

When each condition at each level met

When condition met

Delay
counter

Sequencer

Timer latch

When count ends

When count ends

Instructing MCU to
suspend operation

Buffer-full break
control

Single trace measurement

Enable/Disable
control

Measurement ends

Advertising