2 trace data display examples (raw data), Trace data display examples (raw data) – FUJITSU SOFTUNE F2 MC-16 User Manual

Page 328

Advertising
background image

314

CHAPTER 2 DEPENDENCE FUNCTIONS

2.6.9.2

Trace Data Display Examples (RAW Data)

This section describes trace data that is displayed in the RAW data mode.

■

RAW Data Display

This format displays frames that are output from the emulator without analyzing them.

Figure 2.6-6 shows a RAW data display example.

Figure 2.6-6 Example of the RAW Data Display

frame no.

Displays frame numbers in decimal notation.

address

Displays a branch address.

Branch destination address = 110C6:"-> 000110C6"

Branch source address = 110A8:"000110A8 ->"

mnemonic

Displays the instructions that are executed.

>SHOW TRACE /RAWDATA -10
frame no. address mnemonic
- 00010 : FF00E1 RETI -> FF010E
- 00009 : FF011F BRA

FF010E -> FF010E

- 00008 : FF010E MOVW

A,0190 -> FF00CE [INT]

- 00007 : FF00E1 RETI -> FF010E
- 00006 : FF011F BRA

FF010E -> FF010E

- 00005 : FF010E MOVW

A,0190 -> FF00CE [INT]

- 00004 : FF00E1 RETI -> FF010E
- 00003 : FF011F BRA

FF010E -> FF010E

- 00002 : FF010E MOVW

A,0190 -> FF00CE [INT]

- 00001 : FF00E1 RETI -> FF010E
00000 : ==== << Break at FF0113 >> =====

Decimal, signed

Frame Number

Indicates instruction executed.

Disassemble Description

Hexadecimal Branch
destination address
of branch instruction

Jump address

Break at "address" :
program execution is stopped.

Special frame

Branching by hardware