2 trace data display examples (raw data), Trace data display examples (raw data) – FUJITSU SOFTUNE F2 MC-16 User Manual

Page 328

Advertising
background image

314

CHAPTER 2 DEPENDENCE FUNCTIONS

2.6.9.2

Trace Data Display Examples (RAW Data)

This section describes trace data that is displayed in the RAW data mode.

RAW Data Display

This format displays frames that are output from the emulator without analyzing them.

Figure 2.6-6 shows a RAW data display example.

Figure 2.6-6 Example of the RAW Data Display

frame no.

Displays frame numbers in decimal notation.

address

Displays a branch address.

Branch destination address = 110C6:"-> 000110C6"

Branch source address = 110A8:"000110A8 ->"

mnemonic

Displays the instructions that are executed.

>SHOW TRACE /RAWDATA -10
frame no. address mnemonic
- 00010 : FF00E1 RETI -> FF010E
- 00009 : FF011F BRA

FF010E -> FF010E

- 00008 : FF010E MOVW

A,0190 -> FF00CE [INT]

- 00007 : FF00E1 RETI -> FF010E
- 00006 : FF011F BRA

FF010E -> FF010E

- 00005 : FF010E MOVW

A,0190 -> FF00CE [INT]

- 00004 : FF00E1 RETI -> FF010E
- 00003 : FF011F BRA

FF010E -> FF010E

- 00002 : FF010E MOVW

A,0190 -> FF00CE [INT]

- 00001 : FF00E1 RETI -> FF010E
00000 : ==== << Break at FF0113 >> =====

Decimal, signed

Frame Number

Indicates instruction executed.

Disassemble Description

Hexadecimal Branch
destination address
of branch instruction

Jump address

Break at "address" :
program execution is stopped.

Special frame

Branching by hardware
interrupt

Interrupt

Advertising