1 displaying trace data, Displaying trace data – FUJITSU SOFTUNE F2 MC-16 User Manual

Page 326

Advertising
background image

312

CHAPTER 2 DEPENDENCE FUNCTIONS

2.6.9.1

Displaying Trace Data

This section explains how to display trace data.

Display Formats of Trace Data

The following three formats can be used to display trace data.

RAW data:

Displays trace data without analyzing it.

Instruction:

Displays trace data in the order in which instructions are executed.

Source:

Displays trace data on a source line basis.

Trace Data Display Position

Sampled trace data is numbered by frame. This number is called a "frame number".

When displaying trace data, the starting location in the trace buffer can be specified using the frame number.

Ordinarily, the last sampled trace data is assigned to frame number 0.

How to Display Trace Data

Trace data is displayed in the trace window or command window.

The following two display methods are available, both of which enable you to obtain the same result.

Using trace window

1. Display the trace window.

- Select [View] - [Trace] menu.

2. Select the display mode of the trace window.

- Right-click on the trace window, and select [RAW data], [Instruction], or [Source] from the shortcut

menu.

For details, refer to Section "3.14 Trace Window" in "SOFTUNE Workbench Operation Manual".

3. (If the trace window is already displayed), update trace data.

- Right-click on the trace window, and select [Refresh] from the shortcut menu. Trace data is updated in

the trance window.

For details, refer to Section "3.14 Trace Window" in "SOFTUNE Workbench Operation Manual".

Advertising