134

CHAPTER 2 DEPENDENCE FUNCTIONS

Displaying and Setting External Probe Data

When a command that can use external probe data is executed, external probe data is displayed in 8-digit

binary or 2-digit hexadecimal format. The displayed bit order is in the order of the IC clip cable color code

order (Table 2.2-12). The MSB is at bit7 (Violet), and the LSB is at bit0 (Black). The bit represented by 1

means HIGH, while the bit represented by 0 means LOW. When data is input as command parameters, these

values are also used for input.

Commands for External Probe Data

Table 2.2-13 shows the commands that can be used to set or display external probe data.

Table 2.2-12 Bit Order of External Probe Data

IC Clip

Cable Color

Violet

Blue

Green

Yellow

Orange

Red

Brown

Black

Bit Order

Bit 7

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

External probe data

Table 2.2-13 Commands that can be used External Probe Data

Usable Command

Function

SET SAMPLING
SHOW SAMPLING

Sets sampling timing for external probe
Samples external probe data

SET EVENT
SHOW EVENT

Enables to specify external probe data as condition for event
Displays event setup status

SHOW TRACE

Displays external probe trace-sampled (single trace)

SHOW MULTITRACE

Displays external probe trace-sampled (multi-trace)