9 power-on debugging, Power-on debugging – FUJITSU SOFTUNE F2 MC-16 User Manual

Page 285

Advertising
background image

271

CHAPTER 2 DEPENDENCE FUNCTIONS

2.5.9

Power-On Debugging

This section explains power-on debugging by the emulators for the MB2198.

■

Power-on Debugging

Power-ON debugging refers to the operation to debug the operating sequence that begins when the power to

the target is switched on.

For products with a dedicated power-on debugging terminal, the MB2198 emulator can debug the sequence

performed immediately after power-on. The following functions are available:

•

Code break

•

Data break

•

Sequencer

•

Trace trigger

•

Trace measurement

•

Coverage measurement

The power-on debugging procedure is described below:

•

Set the DIP switch on the adapter board mounted in the upper part of the emulator.

•

Turn on the target board and emulator main unit.

•

Launch Workbench to start debugging.

For debugging, set hardware breaks, etc.

•

To start a power-on debugging, run [Execute] - [Power-ON Debug] menu.

Input the lower limit value of the monitoring voltage from the [User Power Monitor Voltage] dialog box
to display PON in the input status bar.]

•

Run the program.

•

Turn the target board off while running and then back on.

•

Conduct debugging.

•

To terminate the power-on debugging, run [Execute] - [Power-ON Debug] menu.