125

CHAPTER 2 DEPENDENCE FUNCTIONS

2.2.9.2

Display Performance Measurement Data

Display the measured time and measuring count by using the SHOW PERFORMANCE
command.

Displaying Measured Time

To display the time measured, specify the starting event number or the ending event number.

The lower time limit, upper time limit and display interval can be specified. The specified time value is in

1

μs, when the minimum measurement unit timer is set to 1 μs by the SET TIMESCALE command, and in

100 ns when the minimum is set to 100 ns.

>SHOW PERFORMANCE/TIME 1,9000,18999,1000

event

= 1 -> 2

time (

µ

s)

| count

min time

= 11637.0

-----------------------------+---------

max time

= 17745.0

0.0 -

8999.0

|

0

avr time

= 14538.0

9000.0 -

9999.0

|

0

10000.0 -

10999.0

|

0

11000.0 -

11999.0

|

2

12000.0 -

12999.0

|

19

13000.0 -

13999.0

|

52

14000.0 -

14999.0

|

283

15000.0 -

15999.0

|

92

16000.0 -

16999.0

|

3

17000.0 -

17999.0

|

1

18000.0 -

18999.0

|

0

19000.0 -

|

0

-----------------------------+---------

total

|

452

Minimum

execution t ime

Event number

Maximum

execution t ime

Average

execution t ime

Count of measuring within given time interval

Total measuring count

>SHOW PERFORMANCE/TIME 1,13000,16999,500

event = 1 -> 2

time (

μ

s)

| count

min time = 11637.0

-----------------------------+---------

max time = 17745.0

0.0 -

12999.0

|

21

avr time = 14538.0

13000.0 -

13499.0

|

13

13500.0 -

13999.0

|

39

14000.0 -

14499.0

|

121

14500.0 -

14999.0

|

162

15000.0 -

15499.0

|

76

15500.0 -

15999.0

|

16

16000.0 -

16499.0

|

2

16500.0 -

16999.0

|

1

17000.0 -

17499.0

|

1

-----------------------------+---------

total

|

452

Upper time limit for display

Lower time limit for display