149

CHAPTER 2 DEPENDENCE FUNCTIONS

■

Notes on STEP Command

- Exceptional Step Execution

When executing the instructions listed in the notes on the GO command as invalid breakpoints and
abnormal breakpoints, such instructions and the next instruction are executed as a single instruction.
Furthermore, if such instructions are continuous, then all these continuous instructions and the next
instruction are executed as a single instruction.

- Step Execution that won't Break

Note that no break occurs after step operation when both the following conditions are met at one time.

- When step instruction longer than 2 bytes and last code ends at even address

- When breakpoint already set at last address (This "already-set" breakpoint is an invalid breakpoint that

won't break, because it has been set at an address other than the starting address of an instruction.)

■

Controlling Watchdog Timer

It is possible to select "No reset generated by watchdog timer counter overflow" while executing a program

using the GO, STEP, CALL commands.

Use the ENABLE WATCHDOG, DISABLE WATCHDOG commands to control the watchdog timer.

- ENABLE WATCHDOG

:

Reset generated by watchdog timer counter overflow

- DISABLE WATCHDOG

:

No reset generated by watchdog timer counter overflow

The start-up default in this program is "Reset generated by watchdog timer counter overflow".

[Example]

>DISABLE WATCHDOG

>GO