FUJITSU SOFTUNE F2 MC-16 User Manual

Page 163

Advertising
background image

149

CHAPTER 2 DEPENDENCE FUNCTIONS

Notes on STEP Command

- Exceptional Step Execution

When executing the instructions listed in the notes on the GO command as invalid breakpoints and
abnormal breakpoints, such instructions and the next instruction are executed as a single instruction.
Furthermore, if such instructions are continuous, then all these continuous instructions and the next
instruction are executed as a single instruction.

- Step Execution that won't Break

Note that no break occurs after step operation when both the following conditions are met at one time.

- When step instruction longer than 2 bytes and last code ends at even address

- When breakpoint already set at last address (This "already-set" breakpoint is an invalid breakpoint that

won't break, because it has been set at an address other than the starting address of an instruction.)

Controlling Watchdog Timer

It is possible to select "No reset generated by watchdog timer counter overflow" while executing a program

using the GO, STEP, CALL commands.

Use the ENABLE WATCHDOG, DISABLE WATCHDOG commands to control the watchdog timer.

- ENABLE WATCHDOG

:

Reset generated by watchdog timer counter overflow

- DISABLE WATCHDOG

:

No reset generated by watchdog timer counter overflow

The start-up default in this program is "Reset generated by watchdog timer counter overflow".

[Example]

>DISABLE WATCHDOG

>GO