3 specifying displaying trace data start, Specifying displaying trace data start – FUJITSU SOFTUNE F2 MC-16 User Manual

Page 275

Advertising
background image

261

CHAPTER 2 DEPENDENCE FUNCTIONS

2.5.6.3

Specifying Displaying Trace Data Start

The data display start position in the trace buffer can be specified by inputting a step
number or frame number using the SHOW TRACE command. The data display range can
also be specified.

■

Specifying Displaying Trace Data Start

Specify the data display start position in the trace buffer by inputting a step number or frame number using

the SHOW TRACE command. The data display range can also be specified.

[Example]

>SHOW TRACE/RAWDATA -6

; Start displaying from frame -6

>SHOW TRACE/RAWDATA -6..0

; Display from frame -6 to frame 0

>SHOW TRACE -6

; Start displaying from step -6

>SHOW TRACE -6..0

; Displays from step -6 to step 0

Advertising