103

CHAPTER 2 DEPENDENCE FUNCTIONS

2.2.7.5

Sample Flow of Time Measurement by Sequencer

In the following sample, when events are executed in the order of Event 1, Event 2 and
Event 3, the execution time from the Event 1 to the Event 3 is measured. However, no
measurement is made if Event 4 occurs anywhere between Event 1 and Event 3.

Sample Flow of Time Measurement by Sequencer

Start

NO

Branch from level 1 to level 2 (Timer latch 1)

Level 1

YES

Level 2

YES

NO

YES

Sequencer terminates at level 3 (Timer latch 2)

Level 3

YES

NO

YES

End

Event 1

occurs

Event 4

occurs

Event 2

occurs

Event 4

occurs

Event 3

occurs