FUJITSU SOFTUNE F2 MC-16 User Manual

Page 112

Advertising
background image

98

CHAPTER 2 DEPENDENCE FUNCTIONS

[Setup Examples]

- Terminate sequencer when event 1 occurs.

>SET SEQUENCE/EVENT 1,1,J=0

- Terminate sequencer when event 2 occurs 16 times.

>SET SEQUENCE/EVENT 1,2,16,J=0

- Terminate sequencer when event 2 occurs after event 1 occurred. However, do not terminate sequencer

if event 3 occurs between event 1 and event 2.

>SET SEQUENCE/EVENT 1,1,J=2

>SET SEQUENCE/EVENT 2,2,J=0

>SET SEQUENCE/EVENT 2,3,J=1

- Terminate sequencer if and when event 2 occurs less than 300

μs after event 1 occurred.

>SET SEQUENCE/EVENT 1,1,J=2

>SET SEQUENCE/EVENT 2,2,J=0

>SET SEQUENCE/TIMER 2,300,J=1

>SHOW SEQUENCE

Sequencer Enable

level1 level2 level3 level4 level5 level6 level7 level8

1 |1|->2 | |

| | | |

| |

| |

| |

| |

2 | |

|2|->end | | | |

| |

| |

| |

| |

3 | |

| | | |

| |

| |

| |

| |

| |

4 | |

| | | |

| |

| |

| |

| |

| |

5 | |

| | | |

| |

| |

| |

| |

| |

6 | |

| | | |

| |

| |

| |

| |

| |

7 | |

| | | |

| |

| |

| |

| |

| |

8 | |

| | | |

| |

| |

| |

| |

| |

T | |

|T|->1

| | | |

| |

| |

| |

| |

Latch 1 ( -> ) =

Latch 2 ( -> ) =

>SHOW SEQUENCE 2

level no. = 2

event

pass-count

trace-cnt1

jmp-level1

2

1

enable

end

timer

00:00:000:300:000 enable

1

Indicates
move to level
2 when event
1 occurs at
level 1

Indicate s terminating
sequencer when event 2
occurs at level 2.

Indicates move to level 1 if and
when 300

μ

s passed before

event 2 occurs at level 2

Advertising