CHAPTER 2 DEPENDENCE FUNCTIONS

2.2.7.3

Trace Sampling Control by Sequencer

When the event mode is in the normal mode, real-time trace executing tracing called
single trace.
If the trace function is enabled, single trace samples all the data from the start of
executing a program until the program is suspended.

Trace Sampling Control by Sequencer

Sets up suspend/resume trace sampling for each condition at each level of the sequencer. Figure 2.2-8 shows

the trace sampling flow.

For example, it is possible to suspend trace sampling when event 1 occurs, and then resume trace sampling

when event 2 occurs. Trace data sampling can be restricted.

Figure 2.2-8 Trace Sampling Control (1)

As shown in Figure 2.2-9, trace sampling can be disabled during the period from the start of a program

execution until the first condition occurs. For this setup, use the GO command or the SET GO command.

[Example]

>GO/DISABLETRACE

>SET GO/DISABLETRACE

>GO

Figure 2.2-9 Trace Sampling Control (2)

Start

Suspend

Program flow

Trace buffer

Resume

Suspend

Resume

Suspend

Start

Suspend

Program flow

Trace buffer

Resume

Suspend

Resume

Suspend

Resume