2 display performance measurement data, Display performance measurement data – FUJITSU SOFTUNE F2 MC-16 User Manual

Page 201

Advertising
background image

187

CHAPTER 2 DEPENDENCE FUNCTIONS

2.3.7.2

Display Performance Measurement Data

Display the measured time and measuring count by using the SHOW PERFORMANCE
command.

Displaying Measured Time

To display the time measured, specify the starting event number or the ending event number.

>SHOW PERFORMANCE/TIME 1,9000,18999,1000

event

= 1 -> 2

time (

µ

s)

| count

min time

= 11637.0

-----------------------------+---------

max time

= 17745.0

0.0 -

8999.0

|

0

avr time

= 14538.0

9000.0 -

9999.0

|

0

10000.0 -

10999.0

|

0

11000.0 -

11999.0

|

2

12000.0 -

12999.0

|

19

13000.0 -

13999.0

|

52

14000.0 -

14999.0

|

283

15000.0 -

15999.0

|

92

16000.0 -

16999.0

|

3

17000.0 -

17999.0

|

1

18000.0 -

18999.0

|

0

19000.0 -

|

0

-----------------------------+---------

tot

al

|

452

Minimum

execution time

Event number

Maximum

execution time

Average

execution time

Count of measuring within given time interval

Total measuring count

>SHOW PERFORMANCE/TIME 1,13000,16999,500

event = 1 -> 2

time (

µ

s)

| count

min time = 11637.0

-----------------------------+---------

max time = 17745.0

0.0 -

12999.0

|

21

avr time = 14538.0

13000.0 -

13499.0

|

13

13500.0 -

13999.0

|

39

14000.0 -

14499.0

|

121

14500.0 -

14999.0

|

162

15000.0 -

15499.0

|

76

15500.0 -

15999.0

|

16

16000.0 -

16499.0

|

2

16500.0 -

16999.0

|

1

17000.0 -

17499.0

|

1

-----------------------------+---------

total

|

452

Upper time limit for display