Display the measured time and measuring count by using the SHOW PERFORMANCE
command.

■

Displaying Measured Time

To display the time measured, specify the starting event number or the ending event number.

>SHOW PERFORMANCE/TIME 1,9000,18999,1000

event

= 1 -> 2

time (

µ

s)

| count

min time

= 11637.0

-----------------------------+---------

max time

= 17745.0

0.0 -

8999.0

|

0

avr time

= 14538.0

9000.0 -

9999.0

|

0

10000.0 -

10999.0

|

0

11000.0 -

11999.0

|

2

12000.0 -

12999.0

|

19

13000.0 -

13999.0

|

52

14000.0 -

14999.0

|

283

15000.0 -

15999.0

|

92

16000.0 -

16999.0

|

3

17000.0 -

17999.0

|

1

18000.0 -

18999.0

|

0

19000.0 -

|

0

-----------------------------+---------

tot

al

|

452

Minimum

execution time

Event number

Maximum

execution time

Average

execution time

Count of measuring within given time interval

Total measuring count

>SHOW PERFORMANCE/TIME 1,13000,16999,500

event = 1 -> 2

time (

µ

s)

| count

min time = 11637.0

-----------------------------+---------

max time = 17745.0

0.0 -

12999.0

|

21

avr time = 14538.0

13000.0 -

13499.0

|

13

13500.0 -

13999.0

|

39

14000.0 -

14499.0

|

121

14500.0 -

14999.0

|

162

15000.0 -

15499.0

|

76

15500.0 -

15999.0

|

16

16000.0 -

16499.0

|

2

16500.0 -

16999.0

|

1

17000.0 -

17499.0

|

1

-----------------------------+---------

total

|

452