302

CHAPTER 2 DEPENDENCE FUNCTIONS

■

Specifications of Sequencer

Table 2.6-2 shows the specifications of the sequencer for this emulator debugger.

■

How to set

Control the sequencer in the following methods:

●

Sequencer

•

Dialog

- Select [Debug] - [Sequence] menu.

For details, refer to "4.6.6 Sequence" in "SOFTUNE Workbench Operation Manual".

•

Command

1. The event is set according to the SET EVENT command.

2. The event set by the SET SEQUENCE command is set as a sequence.

For details, refer to "3.22 SET EVENT(type 2)" or "3.28 SET SEQUENCE (type2)" in "SOFTUNE
Workbench Command Reference Manual".

Table 2.6-2 Specifications of Sequencer

Function

Specification

No. of levels

2 levels

Restart function

Available (one)

Conditions of each
event
(Code/data)

Address
Pass count: 1 to 1048575
Attribute: Read/write
Data size: Byte, Word, Long
(Attribute and data size can be specified only for data events.)

Operation when
conditions are met

Level 1: Moves to level 2
Level 2: Terminates the sequencer
Restart: Starts the sequencer