184

CHAPTER 2 DEPENDENCE FUNCTIONS

2.3.7

Measuring Performance

It is possible to measure the time and pass count between two events. Repetitive
measurement can be performed while executing a program in real-time, and when done,
the data can be totaled and displayed.
Using this function enables the performance of a program to be measured. To measure
performance, set the event mode to the performance mode using the SET MODE
command.

Performance Measurement Function

The performance measurement allows the time between two event occurrences to be measured and the

number of event occurrences to be counted. Up to 65535 event occurrences can be measured.

Measuring Time

Measures time interval between two events.

Events can be set at 8 points (1 to 8). However, in the performance measurement mode, the intervals, starting

event number and ending event number are combined as follows. Four intervals have the following fixed

event number combination:

Measuring Count

The specified events become performance measurement points automatically, and occurrences of that event

are counted.

Interval

Starting Event Number

Ending Event Number

1 1

2

2 3

4

3 5

6

4 7

8