FUJITSU SOFTUNE F2 MC-16 User Manual

Page 138

Advertising
background image

124

CHAPTER 2 DEPENDENCE FUNCTIONS

Setting Events

Set events using the SET EVENT command.

The starting/ending point of time measurement and points to measure pass count are specified by events.

Events at 8 points (1 to 8) can be set. However, in the performance measurement, the intervals, starting event

number and ending event number are fixed in the following combination.

- Measuring Time

Four intervals have the following fixed event number combination.

- Measuring Count

The specified events become performance measurement points automatically.

Executing Program

Start measuring when executing a program by using the GO or CALL command. If a break occurs during

interval time measurement, the data for this specific interval is discarded.

Displaying Performance Measurement Data

Display performance measurement data by using the SHOW PERFORMANCE command.

Clearing Performance Measurement Data

Clear performance measurement data by using the CLEAR PERFORMANCE command.

[Example]

>CLEAR PERFORMANCE

>

Interval

Starting Event Number

Ending Event Number

1 1

2

2 3

4

3 5

6

4 7

8

Advertising