243

CHAPTER 2 DEPENDENCE FUNCTIONS

2.5.4.1

Code Break

This function aborts a program by monitoring the specified address using hardware or
software. Break occurs prior to execution of the instruction of the specified address.

■

Code Break

This function aborts a program by monitoring the specified address using hardware or software. Break occurs

prior to execution of the instruction of the specified address.

The maximum setting number is as follows:

Hardware

: 4 points

Software

: 2048 points

When a break occurs due to a code break, the following message is displayed on the Status Bar.

•

Hardware

Break at Address by hardware breakpoint

•

Software

Break at Address by breakpoint

■

Setting Method

The code break is controlled by the following method.

•

Command

- SET BREAK/HARD (Hardware)

- SET BREAK/SOFT (Software)

Refer to "3.1 SET BREAK (type 1)" in "SOFTUNE Workbench Command Reference Manual".

•

Dialog

- Breakpoints set dialog [Code] tab

Refer to "4.6.4 Breakpoint" in "SOFTUNE Workbench Operation Manual".

•