102

CHAPTER 2 DEPENDENCE FUNCTIONS

2.2.7.4

Time Measurement by Sequencer

Time can be measured using the sequencer. A time measurement timer called the
emulation timer is used for this purpose. When branching is made from a specified level
to another specified level, a timer value is specified. Up to two emulation timer values can
be fetched. This function is called the timer latch function.

■

Time Measurement by Sequencer

The time duration between two given points in a complex program flow can be measured using the timer

latch function.

The timing for the timer latch can be set using the SET SEQUENCE command; the latched timer values can

be displayed using the SHOW SEQUENCE command.

When a program starts execution, the emulation timer is initialized and then starts counting. Select either 1

μs

or 100 ns as the minimum measurement unit for the emulation timer. Set the measurement unit using the SET

TIMESCALE command.

When 1

μs is selected, the maximum measured time is about 70 minutes; when 100 ns is selected, the

maximum measured time is about 7 minutes. If the timer overflows during measurement, a warning message

is displayed when the timer value is displayed using the SHOW SEQUENCE command.