112

CHAPTER 2 DEPENDENCE FUNCTIONS

2.2.8.4

Setting Multi Trace

Before executing the multi trace, the following settings must be made. After these
settings, trace data is sampled when a program is executed.
(1) Set event mode to multi trace mode.
(2) Enable trace function.
(3) Set event.
(4) Set trace-buffer-full break.

Setting Multi Trace

Before executing the multi trace, the following settings must be made. After these settings, trace data is

sampled when a program is executed.

(1) Set event mode to multi trace mode.

Use the SET MODE command for this setting.

(2) Enable trace function.

Use the ENABLE MULTITRACE command. To disable the function, use the DISABLE MULTITRACE
command.

(3) Set event.

Set an event that sampling. Use the SET EVENT command for this setting.

(4) Set trace-buffer-full break.

To break when the trace buffer becomes full, set the trace-buffer-full break. Use the SET MULTITRACE
command for this setting.

Table 2.2-11 shows the list of trace-related commands that can be used in multi trace mode.

Table 2.2-11 Trace-related Commands That Can Be Used in Multi Trace Mode

Usable Command

Function

SET EVENT
SHOW EVENT
CANCEL EVENT
ENABLE EVENT
DISABLE EVENT

Sets events
Displays event setup status
Deletes event
Enables event
Disables event

SET MULTITRACE
SHOW MULTITRACE
SEARCH MULTITRACE
ENABLE MULTITRACE
DISABLE MULTITRACE
CLEAR MULTITRACE

Sets trace-buffer-full break
Displays trace data
Searches trace data
Enables multi trace
Disables multi trace
Clears trace data